Поддержка нового оборудования
Trimble T10 cirronet radio
Trimble Access version 2017.11 now supports the internal cirronet radio in the new Trimble T10 tablet.
Trimble SPS986 receiver
Trimble Access version 2017.11 supports the new Trimble SPS986 receiver.
S-Max GEO receiver
Trimble Access version 2017.11 supports the S-Max GEO receiver.
Software changes
Changes to auto‑connect for FOCUS 30/35 total stations
In Trimble Access, auto‑connect to Spectra Geospatial FOCUS 30/35 total stations is no longer enabled by default. When auto‑connect to a FOCUS total station is enabled it can cause problems connecting to an S Series total station. You can enable auto‑connect for either Trimble VX/S Series total stations or FOCUS 30/35 total stations, but not both at the same time. To enable auto‑connect to a FOCUS total station, tap the auto‑connect icon in the status bar, then select FOCUS 30/35 and tap Accept.
Camera softkey available on Windows 10 tablets
The Camera softkey is now available in attribute entry screens when running Trimble Access on a Windows 10 tablet. Tap the Camera softkey to open the camera application on the tablet. If the tablet has multiple cameras, the softkey will open the front facing camera so you may wish to toggle to the rear facing camera for image capture to populate the current feature attribute field.
If the controller is connected to an instrument with Vision technology, two Camera softkeys are available, one for the controller camera and one for the instrument camera.
Estimate of power remaining in external battery
An estimate of the percentage of usable power remaining in an external battery attached to the connected GNSS receiver has been reinstated.
Coordinate system database changes
- Added coordinate system definitions for Cyprus
- Added the following new UTM Zones for Germany: UTM Zone 31 (zE-N), UTM Zone 32 (zE-N) and UTM Zone 33 (zE-N)
- Renamed Germany / Ascos systems to Germany / AxioNet systems
- Added Indian Kalianpur 1975 coordinate system definitions
- Added GDA2020 coordinate system definitions for Australia
- Added ITRF2014 datum definition
Устраненные проблемы
- Dual-prism offsets with video: An issue when measuring a topo point using a dual-prism offset, where after switching to the Video screen before the second observation, the software returned to the main menu upon completion instead of the Measure topo screen allowing you to continue subsequent measurements, is now resolved.
- DTM display issues on tablet controllers: A number of issues on tablet controllers for surfaces with elevation values greater than 100m are now resolved, including:
- the surface displayed as black in the map if the surface settings were set to Display color gradient.
- points with an elevation near the value of the surface were displayed in the map with an elevation of around 0m. This was a display issue only. The points had the correct elevation.
- points keyed in by tapping and holding on the map where the point was over part of the surface resulted in incorrect elevations of around 0m, when the elevation should have been the elevation of the surface at that position.
- cut/fill values displayed were incorrect when surveying relative to a DTM.
- Measure softkeys in Stakeout screen: An issue when using a Trimble C5 total station, where the MSR and MSR2 keys in the Stakeout screen did not initiate a measurement is now resolved.
- Delta display when tracking mode disabled: An issue when running Trimble Access on a Trimble C5 total station, where if the Use TRK mode for stakeout option was not selected in the Stakeout options screen (or in the Stakeout options screen of the survey style) then the delta display was sometimes not being updated after completing a measurement using the Measure softkey, is now resolved.
- Tilt warning: An incorrect Receiver not level warning when using RTX QuickStart with an R10 receiver that has an expired tilt calibration has been removed.
- QZSS satellites: The satellite information screen now correctly displays the new QZSS satellites with PRNs greater than 195.
-
Feature coded linework: An issue when using base numeric codes that end with a decimal point (.) is now resolved. This issue was introduced in Trimble Access version 2016.10.
- Exporting alphanumeric feature codes to DXF: An issue where alphanumeric features codes with appended numbers were not placed into the correct layer when exporting to DXF if the alphabetical part of the code was not in the feature code library is now resolved.