To stake out additional strings
This stakeout method is only available when you are working from the map and graphical screens, not the menu.

-
Tap the string, or from the tap and hold menu tap Select additional string and then select the string from the list.
- To stake points offset from the road, leaving the roadway clear for construction, define a construction offset.
- To confirm the construction of the road surface, define a cross slope.
- Tap Start.
-
Use the plan or cross section view to navigate relative to the string. See Stakeout navigation.
-
When the point is within tolerance, tap Measure to measure the point.When using a Trimble SX12 scanning total station in TRK mode with the laser pointer enabled, the Stakeout screen shows the Mark point softkey instead of the Measure softkey. Tap Mark point to put the instrument into STD mode. The laser pointer stops flashing and moves to position itself at the EDM location. When you tap Accept to store the point, the instrument automatically returns to TRK mode and the laser pointer resumes flashing. To remeasure and update the stakeout deltas, tap Measure after you tap Mark point and before you tap Accept. For more information, see EDM settings.Tap Store.
The software returns to the navigation screen.
- Continue selecting and measuring points along the road.
- To exit this stakeout method, tap Esc.

-
Tap the station on the additional string. To select the string and station from a list, from the tap and hold menu tap Select additional string and then from the tap and hold menu tap Select additional station.
- To stake points offset from the road, leaving the roadway clear for construction, define a construction offset.
- To confirm the construction of the road surface, define a cross slope.
- To stake points on road surfaces other than the finished road surface, define a subgrade.
- Tap Start.
- Use the plan or cross section view to navigate to the point. See Stakeout navigation.
-
When the point is within tolerance, tap Measure to measure the point.When using a Trimble SX12 scanning total station in TRK mode with the laser pointer enabled, the Stakeout screen shows the Mark point softkey instead of the Measure softkey. Tap Mark point to put the instrument into STD mode. The laser pointer stops flashing and moves to position itself at the EDM location. When you tap Accept to store the point, the instrument automatically returns to TRK mode and the laser pointer resumes flashing. To remeasure and update the stakeout deltas, tap Measure after you tap Mark point and before you tap Accept. For more information, see EDM settings.Tap Store.