To adjust a FOCUS 30/35 total station
- Set up the instrument on a stable surface.
- Make sure that the instrument is accurately leveled and that the compensator is enabled.
-
Tap
and select Instrument / Adjust.
The procedures available in the Adjust screen depend on the connected instrument.
- Perform each adjustment in turn, using the steps below.

-
Position the instrument so that the angle to the point is less than 4°30' (5 gon) from the horizontal plane.
-
Select Collimation.
Current adjustment values for the instrument are shown.
- Tap Next.
-
Aim at the point and take the collimation measurement.
Do not use Autolock during collimation or trunnion axis tilt tests.
You must take a minimum of one observation on each face. If you take more than one observation, complete all observations on face 1 first. Between each observation, turn the instrument away and then re‑aim.
- To change face, tap Chg face and observe the same number of observations on face 2 as you observed on face 1.
-
When the number of observations is the same for both faces, tap Results.
The current values and the new instrument values are shown.
- Tap Accept.

-
Position the instrument so that the angle to the point is less than 13°30' (15 gon) from the horizontal plane.
-
Select Trunnion axis tilt.
Current adjustment values for the instrument are shown.
- Tap Next.
-
Aim at the point and take the trunnion axis tilt measurement.
Do not use Autolock during collimation or trunnion axis tilt tests.
You must take a minimum of one observation on each face. If you take more than one observation, complete all observations on face 1 first. Between each observation, turn the instrument away and then re‑aim.
- To change face, tap Chg face and observe the same number of observations on face 2 as you observed on face 1.
-
When the number of observations is the same for both faces, tap Results.
The current values and the new instrument values are shown.
- Tap Accept.

Autolock collimation should be performed after the HA VA Collimation adjustment, if available, has been completed.
- Select Autolock collimation.
- Follow the prompts.
- Sight to a target on face 1 with a slope distance between 20 m and 300 m and within 4°30 (5 gon) of horizontal.