Image technology

The instrument is equipped with a total of four cameras: overview camera, primary camera, tele camera and plummet camera. Each camera performs a different task.

Overview camera

The overview camera is positioned parallel with the EDM axis but with an offset. It has a fixed focus with a 54° field of view.

The overview camera is used for the following zoom levels:

  • Zoom level 1-2 when the laser pointer is off.

  • Zoom level 1-2 when the laser pointer is on.

Primary camera

The primary camera is positioned parallel with the EDM axis but with an offset. It has a fixed focus with a 12° field of view.

The primary camera is used for the following zoom levels:

  • Zoom level 3-4 when the laser pointer is off.

  • Zoom level 3-6 when the laser pointer is on.

Tele camera

The tele camera is positioned coaxial with the EDM axis. It is equipped with an auto focus with a 2° field of view.

The tele camera is used for the following zoom levels:

  • Zoom level 5-8 when the laser pointer is off.

  • The tele camera is not used when the laser pointer is on. The tele camera and laser pointer share the same optical path, and so only one may be used at a time.

Zoom level Laser pointer off Laser pointer on
1

Overview camera

Overview camera

2

Overview camera

Overview camera

3

Primary camera

Primary camera

4

Primary camera

Primary camera

5

Tele camera

Primary camera

6

Tele camera

Primary camera

7

Tele camera

N/A
8

Tele camera

N/A

Plummet camera

The plummet camera is a camera-based solution that replaces the optical plummet. It has a fixed focus with a 6° field of view. The plummet camera can be used to document your setup. Click the camera symbol in the display to take a snap shot.

NOTE – The orientation of the plummet camera is aligned to a user standing at the back side of the instrument. See Set up over a point.