Check Graphically a Registration Quality
Once a registration between stations has been performed, beside reviewing the registration results (see Display Refinement Report), you can check the quality graphically. Do one of the following:

Choose and select a station. The application hides all other stations except the selected one and the station(s) close to the selected one. The number of nearest stations has to be defined in
Settings > General.
Tap to reload all stations.

Tap , set a value in meter (or foot) in the Adjust Magnifier Size and pick a point on the scan data in the Map View (or in the Station View). The picked point defines the center of a clipping box and the application loads more points inside the clipping box.
-
If one station is displayed in the Map View, only points from that station are loaded in the clipping box in the Map View.
-
If one station is displayed in the Station View, the application displays all stations in the Map View, and loads points from all stations (including hidden ones) in the clipping box.
The minimum and maximum sizes of the clipping box are 0.1 m and 10 m (or 0.25 ft and 32.81 ft).
Tap or
to increase or to decrease the step size by:
-
0.5 m (or 1 ft) when the value is between 0.5 m (or 1.64 ft) and 9.5 m (or 31.17 ft).
-
0.1 m (or 0.25 ft) when the value is below 0.5 m (or 1 ft).
Tap to set the maximum value (10 m or 32.81 ft) when the value is above 9.5 m (or 31.17 ft).
Tap to set the minimum value (0.1 m or 0.25 ft) when the value is below 0.2 m ( 0.5 ft).
Tap to reload all the scan data.