Default receiver settings

All settings are stored in application files. The default application file, Default.cfg, is stored permanently in the receiver, and contains the factory default settings. Whenever the receiver is reset to its factory defaults, the current settings (stored in the current application file, Current.cfg) are reset to the values in the default application file.

You cannot modify the default application file. However, you can create a power-up application file so that the settings in this file can be applied immediately after the default application file, overriding the factory defaults. For more information, see Resetting the receiver to factory defaults.

These settings are defined in the default application file.

Function

Settings

Factory default

SV Enable (see Satellite Enable/Disable)

All SVs enabled

General Controls

Elevation mask

10°

PDOP mask

7

RTK positioning mode

Low Latency

Motion

Kinematic

Serial Port 3

Baud rate

38,400

Format

8-None-1

Flow control

None

Serial Port (Modem) 2

Baud rate

38,400

Format

8-None-1

Flow control

None

Input Setup

Station

Any

NMEA/ASCII (all support messages)

 

None

Streamed Output (see I/O Configuration – Port Configuration)

 

All types Off

Offset=00

RT17/Binary (see RT17/RT27)

 

All ports Off

RTX/OmniSTAR (see MSS Configuration)

Internal demodulator

Off

Antenna (see Antenna Configuration)

Type

Zephyr 3 Base

Height (true vertical)

0.00 m

Measurement method

Antenna Phase Center

Autobase (see AutoBase settings)

 

Enabled without Warning